DG Set with Volvo Eicher Engine



Specifications :


PARAMETERS DG MODELS
Duty (Standby/ Prime) Stand By
50 HZ PRIME Rating(kVA) 35 kVA
Rated(kWe) 35
Engine Model 3445 TCIGM-C2
No of Phases 1/3
No of Cylinders 3
Output Voltage (V) 230V/415V
Current (A) (1Phase / 3Phase) 152.2 / 48.7
Power Factor (lagging) 0.8
Frequency (Hz)/ RPM 50/1500
Governing class A1
Starting system 12 V DC Elec
Fuel Tank Capacity (lits) 115
Genset Dimension (LxWxH $$) (mm) Approx. 3 Phase :- 2000 X 980 X 1280
1 Phase :- 2200 X 980 X 1280
Genset Weight (Kg), Appx 3 Phase :- 926
1 Phase :- 984
Make Mahindra
Power Output# (HP) 44
Aspiration Turbocharged & Intercooled
No of Cylinders 3
Bore x Stroke (mm) 88.9 X 110
Displacement (cc) 2048
Fuel consumption @ 75% load (lit/hr) ^ -
Fuel consumption @ 100% load (lit/hr) ^ -
Lube oil specification SAE15W40 CI4
Total Lube Oil capacity (lit) 7
Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption
Lube oil change period (hrs.) 300 hrs. for Oil Top Up
600 hrs. for Oil change
Radiator coolant capacity (liter) 9.5
Alternator
Enclosure Type CG/LS
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%